Emer

Pressure Relief Device (Temperature Triggered with Bulb)

PRDB

Pressure Relief Device (Temperature Triggered with Bulb) PRDB

Pressure Relief Device that is activated by high pressure allowing fluid to flow outside, it is a non-reclosing device.

Features

  • End plug temperature safety device
  • Temperature triggered with bulb
  • OEM approved product range
  • Complete in-house manufacturing
  • Available with different thread to connect the pipe to vent the gas in case of activation

Technical Specifications

Material Brass
Operating temperature -40 °C » +120 °C
Max. working pressure 260 bar
Minimum gas flowing area Ø 6 mm
Activation temperature 110 ± 10 °C
Approvals ISO 15500, R110

Options

Type
(seal)
Frontal O-Ring
On the conical thread
Connection size M16x1
W 28,8
1/4" 18 NPT
1" 1/8